Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

You may have noticed that the liquid flows right through the floor, and disappears. This means our Simulator is open and needs to be closed. In the Grid rollout, under Boundary Conditions Container Walls, set the X, Y, and Z axes to Jammed Both. Running the simulation again will now result in the liquid colliding with the bottom and side walls of the volume.

...

Next, select the simulator, and in the Grid section, under Boundary Conditions Container Walls, set the X, Y, and Z walls to be Open. This will keep any of those droplets from colliding with the imaginary walls.

...